Home Products
Home UPS-Flooded Flat Plate,Tall STANFLAT Range
Features
Lug type Terminals   Electrolyte level indicator for easy top-up
Heat Sealed Tamper proof Leads Tower Type design
Rope type Lifting arrangement User Friendly
   

Advantages

Extra Heavy Duty Thicker Plates ensures Durability, Resistance to Corrosion, and Inbuilt Margins for High Ambient Temperature   High Acid Volume per AH ensuring Low Maintenance Characteristics
Built with PE Pocket type Separator bonded with Glass Mat for extra support to Active Material, making the Battery more suitable for Deep Cycle Application Suitable for Long and Frequent Power-cuts with Quick Recharge Adaptability
  Substantial saving in Floor Area
    Resistance to Abuse
    Rugged Polypropylene Container

Applications

Home UPS & Inverters    
     
 
The STANFLAT - SF  Series
SPECIFICATIONS CHART
Battery
Type
Nominal
Volts
Rated Capacity (Ah) at 27°C (1.280 sp.gr.) Dimensions (mm)±3mm Weight±5%,(Kg)
20 Hr @ 1.75V/Cell 10 Hr @ 1.75V/Cell 5 Hr @ 1.75V/Cell 3 Hr @
1.75V/Cell
1 Hr @
1.75V/Cel
Length Width Height* Dry Filled
STANFLAT1800 12 180 150 132 117 87 500 187 430 36.50 62.50
STANFLAT2000 12 200 175 154 137 102 500 187 430 47.77 72.50

* the height mentioned is up to terminal top.

 
BATTERY CHARGING SCHEDULE
Battery
Type
Nominal
Volts
Rated Capacity (Ah)
at 27°C, 20 Hr @ 1.75V/Cell
Initial Charge at Constant Current (A) Minimum Ah Input During Initial Charge Approx. Acid Qty (1.220 Sp. Gr.) in ltrs/Cell Constant Potential Limiting Current (A) Trickle Charge Current (mA)
Start (upto 2.36 vpc) Finish (upto 2.75 vpc) Min Max
STANFLAT1800 12 180 18.00 9.00 525 3.55 30.0 150 600
STANFLAT2000 12 200 21.00 10.50 615 3.35 44.0 175 700
 
Initial Charging Instructions:
Filling in Specific Gravity 1.220±0.005 at 27 °C  

In case the temperature exceeds 50°C, adequate rest to be given till the electrolyte temperature comes to ambient temp. and charging to be continued

Rest period 4 - 6 Hrs.

In case the temperature exceeds 50°C, adequate rest to be given till the electrolyte temperature comes to ambient temp. and charging to be continued
Minimum Ah input as per above chart. Condition of fully charged –
In order to reduce the charging time, the initial charging current would be as specified till 2.36 Volts/Cell followed by finishing current as specified till 2.75 Volts/Cell.  
  3 consecutive hourly readings of specific gravity and voltage become constan
  Top of charge voltage will be around 16.2V – 16.5V
  All cells should gas freely.
  Minimum Ah has been given
However in both cases, Minimum Ah input to be given. Under no circumstances, battery temperature should exceed 50°C.   Specific gravity at fully charged condition – 1.250±0.005 at 27°C
 

Normal Recharging Instructions

Battery should be re-charged through an Inverter at constant potential mode of 14.4V with limited current as specified. After battery potential reaches 14.4V, the battery should continue in float charge mode at constant potential of 13.8V.
 

Statutory Notice

All batteries contain lead, which is harmful for humans and environment. As per statutory requirements, the used battery must be returned to the authorized dealer, manufacturer or at the designated collection centers.

 
 

 
 
 
  Copyright © 2017 SF Industrial. All Rights Reserved. Powered By